SIC Technical Info

HYDRO-MAXX™ Servo Integrated Controller (SIC)

SYSTEM

Power Requirements:

  • 12 VDC, .5 Amp supply, controller
  • 12 VDC, up to 60 amps for output supply (dependent on application)

Operating Temp range:

  • -40F- 140F
  • -40C- 60C

Humidity: 90% non-condensing

Vibration/ Shock: TBD/ 1G

CONTROLLER

Micro-Processor:

  • 4MHZ Clock
  • CPU Speed 5 MIPS
  • CMOS FLASH-based 8-bit microcontroller,
  • 256 bytes of EEPROM
  • RAM Bytes 368
  • ADC up to 8 ch, 10 bit

I2C™ Serial Bus Interface for up to 256 devices

COMM:

  • Serial (RS232)
  • USB
  • Optional Bluetooth™ will be available in the future

System Inputs:

  • 8 Pre-defined, 5VDC, 5-20 mamps, source sinking input.

System Outputs:

10 Pre-defined, 5VDC

  • 4- PWM outputs
  • 6- Digital outputs

6- Hi Current MOSFET outputs, 50Amp rated device

4- PWM:

  • 3- 1Amp
  • 1- 7.5Amp

1-  HHO Cell Digital Output:

  • 20mAmp driver
  • 6 modules available
  • 20-225 DC Amps continuous

60-600 VDC with optional Power Output Modules (POM), (see chart below)

Analog output available (Optional)

AC output also available (Optional)

NOTE: Multiple Power output modules can be added in series. i.e. 600 + 600 = 1,200Amp output

CURRENT SENSING (Optional)

  1. Current control (Servo)
  2. Current shut off

TEMPERATURE SENSOR (Optional)

  1. Temperature control (Servo)
  2. Temperature shut off

Temperature Sensing Range:

-40C – 125C

± 2*c  max accuracy from +25*c- +25*c
±3*c  max accuracy from +0*c- +125*c
±2*c  max accuracy from -40*c- -0*c

Polling Frequency

  • 100Khz
  • Range-40*c – +185*c

I2C™  Serial Port Interface up to 8 sensors can be used

Output: 8bit digital word

FLUID MONITORING

  • Fluidic State (Optional)
  • Level Sensing (Optional)

Tank Sensors:

  • Hi Level
  • Low Level

AUTO REFILL (Optional)

For each main fluid tank;

  • Refill Tank
  • Pump
  • Solenoid Valve
  • Fluid Level Switch
  • Indicating Light
  • Hoses
  • Fittings

Fluid Heater (optional)

PUMP CONTROL

  1. PWM  Control
  2. Steady state (On/Off)

AUXILIARY CONTROL

  1. PWM Control
  2. Steady state (On/Off)

ENVIRONMENTAL CONTROL SYSTEM:

  • ECS (Optional),
  • Integrated Heating/Cooling system for use in Severe Weather Applications
  1. PWM Control
  2. Steady state (On/Off)