SIC Technical Info
HYDRO-MAXX™ Servo Integrated Controller (SIC)
SYSTEM
Power Requirements:
- 12 VDC, .5 Amp supply, controller
- 12 VDC, up to 60 amps for output supply (dependent on application)
Operating Temp range:
- -40F- 140F
- -40C- 60C
Humidity: 90% non-condensing
Vibration/ Shock: TBD/ 1G
CONTROLLER
Micro-Processor:
- 4MHZ Clock
- CPU Speed 5 MIPS
- CMOS FLASH-based 8-bit microcontroller,
- 256 bytes of EEPROM
- RAM Bytes 368
- ADC up to 8 ch, 10 bit
I2C™ Serial Bus Interface for up to 256 devices
COMM:
- Serial (RS232)
- USB
- Optional Bluetooth™ will be available in the future
System Inputs:
- 8 Pre-defined, 5VDC, 5-20 mamps, source sinking input.
System Outputs:
10 Pre-defined, 5VDC
- 4- PWM outputs
- 6- Digital outputs
6- Hi Current MOSFET outputs, 50Amp rated device
4- PWM:
- 3- 1Amp
- 1- 7.5Amp
1- HHO Cell Digital Output:
- 20mAmp driver
- 6 modules available
- 20-225 DC Amps continuous
60-600 VDC with optional Power Output Modules (POM), (see chart below)
Analog output available (Optional)
AC output also available (Optional)
NOTE: Multiple Power output modules can be added in series. i.e. 600 + 600 = 1,200Amp output
CURRENT SENSING (Optional)
- Current control (Servo)
- Current shut off
TEMPERATURE SENSOR (Optional)
- Temperature control (Servo)
- Temperature shut off
Temperature Sensing Range:
-40C – 125C
± 2*c max accuracy from +25*c- +25*c
±3*c max accuracy from +0*c- +125*c
±2*c max accuracy from -40*c- -0*c
Polling Frequency
- 100Khz
- Range-40*c – +185*c
I2C™ Serial Port Interface up to 8 sensors can be used
Output: 8bit digital word
FLUID MONITORING
- Fluidic State (Optional)
- Level Sensing (Optional)
Tank Sensors:
- Hi Level
- Low Level
AUTO REFILL (Optional)
For each main fluid tank;
- Refill Tank
- Pump
- Solenoid Valve
- Fluid Level Switch
- Indicating Light
- Hoses
- Fittings
Fluid Heater (optional)
PUMP CONTROL
- PWM Control
- Steady state (On/Off)
AUXILIARY CONTROL
- PWM Control
- Steady state (On/Off)
ENVIRONMENTAL CONTROL SYSTEM:
- ECS (Optional),
- Integrated Heating/Cooling system for use in Severe Weather Applications
- PWM Control
- Steady state (On/Off)